Useful in process control as well as environmental studies, this powerful waterproof instrument, which has four ranges capable of measuring concentrations from 0.150g/L to 300g/L, can be used in a laboratory but is tough enough to travel to the field.
Features:

  • HI 931100 measures four salinity ranges
  • Tutorial messages on LCD display
  • Calibration reminder
  • Displays parameter and temperature readings simultaneously
  • Automatic calibration
  • Dual-level LCD
  • 2-year meter warranty

HI 931100 is an ion-selective meter that uses a sodium electrode to read the salt (NaCl) content of a solution. The meter uses an FC 300 B glass body sodium ISE probe with BNC connector and 1 meter cable (purchase separately).

This powerful meter auto ranges from sample to sample over an extremely broad range without the need for recalibration making it easy-to-use.  It has four measuring ranges, capable of measuring concentrations from 0.150 g/L to 300 g/L.

A separate temperature probe, HI 7662, provides temperature readings from -20 to 120°C (purchase separately).

Specifications:

Range NaCl 0.150 to 1.500 g/L NaCl
1.50 to 15.00 g/L NaCl
15.0 to 150.0 g/L NaCl
150 to 300 g/L NaCl
°C -20.0 to 120.0ºC (-4.0 to 248.0ºF)
Resolution NaCl 0.001 g/L NaCl
0.01 g/L NaCl
0.1 g/L NaCl
1 g/L NaCl
°C 0.1°C (0.1ºF)
Accuracy (@20°C) NaCl ±5% of reading (NaCl)
°C ±0.2°C (±0.4ºF) (excluding probe error)
Calibration automatic, one or two point at 0.30 g/L (HI 7085), 3.00 g/L (HI 7083), 30.0 g/L (HI 7081)
Temperature Compensation fixed at 25°C (77°F)
Electrode FC 300B glass body sodium ion electrode with BNC connector and 1 m (3.3’) cable (not included)
Temperature Probe HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (not included)
Input Impedance 1012 Ohm
Battery Type / Life 1.5V AA (4) / approx. 200 hours of continuous use
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 185 x 72 x 36 mm (7.3 x 2.8 x 1.4’’)
Weight 300 g (10.6 oz.)

Useful in process control as well as environmental studies, this powerful waterproof instrument, which has four ranges capable of measuring concentrations from 0.150g/L to 300g/L, can be used in a laboratory but is tough enough to travel to the field.
Features:

  • HI 931100 measures four salinity ranges
  • Tutorial messages on LCD display
  • Calibration reminder
  • Displays parameter and temperature readings simultaneously
  • Automatic calibration
  • Dual-level LCD
  • 2-year meter warranty

HI 931100 is an ion-selective meter that uses a sodium electrode to read the salt (NaCl) content of a solution. The meter uses an FC 300 B glass body sodium ISE probe with BNC connector and 1 meter cable (purchase separately).

This powerful meter auto ranges from sample to sample over an extremely broad range without the need for recalibration making it easy-to-use.  It has four measuring ranges, capable of measuring concentrations from 0.150 g/L to 300 g/L.

A separate temperature probe, HI 7662, provides temperature readings from -20 to 120°C (purchase separately).

Specifications:

Range NaCl 0.150 to 1.500 g/L NaCl
1.50 to 15.00 g/L NaCl
15.0 to 150.0 g/L NaCl
150 to 300 g/L NaCl
°C -20.0 to 120.0ºC (-4.0 to 248.0ºF)
Resolution NaCl 0.001 g/L NaCl
0.01 g/L NaCl
0.1 g/L NaCl
1 g/L NaCl
°C 0.1°C (0.1ºF)
Accuracy (@20°C) NaCl ±5% of reading (NaCl)
°C ±0.2°C (±0.4ºF) (excluding probe error)
Calibration automatic, one or two point at 0.30 g/L (HI 7085), 3.00 g/L (HI 7083), 30.0 g/L (HI 7081)
Temperature Compensation fixed at 25°C (77°F)
Electrode FC 300B glass body sodium ion electrode with BNC connector and 1 m (3.3’) cable (not included)
Temperature Probe HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (not included)
Input Impedance 1012 Ohm
Battery Type / Life 1.5V AA (4) / approx. 200 hours of continuous use
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 185 x 72 x 36 mm (7.3 x 2.8 x 1.4’’)
Weight 300 g (10.6 oz.)