Offline UPS (650VA to 2000VA)

0.00৳ 

HIGH RELIABILITY

  • Advanced digital control technology
  • Comprehensive equipment protection function
  • Flexible and practical cold start function

EXCELLENT PERFORMANCE

  • Stable operation without noise
  • Green idea environment design
  • Wide voltage range for intellectual regulation (Smart AVR)

EASY FOR USE

  • Small size, easy operation
  • Intelligent and use-friendly power management (optional)

Technical Data

Item UPS 650VA-2000VA
Input/ Output wiring L+N+PE
Input Voltage UPS650/UPS1200/UPS1500/UPS2000/ 140~280Vac
Input Frequency 50/60±10%Hz
Output Voltage 220/230 ±10% Vac (Battery mode)
Output Frequency Synchronizing with input AC while it is normal, and 50/60±0.5%Hz on battery mode
Transfer Time Typical 6ms, including detection time and switching time (Synchronous switch-over)
Waveform Square wave / Pure sine wave (Option-2)
Battery Voltage UPS 650 VA12Vdc
UPS1200: 24Vdc
UPS1500/UPS2000: 24/48Vdc
Max. Charging Current UPS 650/1200VA/1500VA/ 2000 VA : 1A (Short backup)
UPS 650/1200VA/1500VA/ 2000 VA : 6-8A (Long backup)
Display LED indicators show status of AC input, inverter, low battery and overload
RS 232 (USB, SNMP adaptor are optional)

HIGH RELIABILITY

  • Advanced digital control technology
  • Comprehensive equipment protection function
  • Flexible and practical cold start function

EXCELLENT PERFORMANCE

  • Stable operation without noise
  • Green idea environment design
  • Wide voltage range for intellectual regulation (Smart AVR)

EASY FOR USE

  • Small size, easy operation
  • Intelligent and use-friendly power management (optional)

Technical Data

Item UPS 650VA-2000VA
Input/ Output wiring L+N+PE
Input Voltage UPS650/UPS1200/UPS1500/UPS2000/ 140~280Vac
Input Frequency 50/60±10%Hz
Output Voltage 220/230 ±10% Vac (Battery mode)
Output Frequency Synchronizing with input AC while it is normal, and 50/60±0.5%Hz on battery mode
Transfer Time Typical 6ms, including detection time and switching time (Synchronous switch-over)
Waveform Square wave / Pure sine wave (Option-2)
Battery Voltage UPS 650 VA12Vdc
UPS1200: 24Vdc
UPS1500/UPS2000: 24/48Vdc
Max. Charging Current UPS 650/1200VA/1500VA/ 2000 VA : 1A (Short backup)
UPS 650/1200VA/1500VA/ 2000 VA : 6-8A (Long backup)
Display LED indicators show status of AC input, inverter, low battery and overload
RS 232 (USB, SNMP adaptor are optional)

Reviews

There are no reviews yet.

Be the first to review “Offline UPS (650VA to 2000VA)”

Your email address will not be published. Required fields are marked *