Muffle Furnaces up to 1100 °C or 1200 °C, L 3/11 – LT 60/12, 1L to 60L
The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
- Model: L (T) Series
- Volume: 1L to 60L
- Brand: Nabertherm
- Country of Origin: Germany
- Country of Manufacture: Germany
MUFFLE FURNACES UP TO 1400 °C Nabertherm is one of the world’s leading manufacturers of laboratory furnaces based in Lilienthal near Bremen. We probably offer the widest range of muffle furnaces, drying ovens, high-temperature furnaces or tube furnaces.
With more than 70 years of experience and one of the largest engineering departments in the furnace industry, the name Nabertherm stands for high quality “Made in Germany”, future-oriented innovations, worldwide service and reliability. More than 100,000 customers in over 100 countries underline this.
Contact us directly, one of our global sales offices or our network of long-term trading partners. We would be happy to advise you so that your research and development will also be a complete success.
The muffle furnaces L 3/11 – LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
- Tmax 1100 °C or 1200 °C
- Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 – LT 60/12) for an optimal temperature uniformity
- Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
- Thermocouple type N (1100 °C) or type S (1200 °C)
- Ceramic heating plates with integral heating element which is safeguarded and easy to replace
- Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
- Dual shell housing made of textured stainless-steel sheets with additional fan cooling for low surface temperature
- Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
- Adjustable air inlet integrated in door (see illustration)
- Exhaust air outlet in rear wall of furnace
- Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
- Solid state relays provide for lownoise operation
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
- have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
- Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
- Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
- Protective gas connection to purge with non-flammable protective or reaction gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
- Manual or automatic gas supply system
- Port for thermocouple in the rear wall or in the furnace door
- Process control and documentation via VCD software package for monitoring, documentation and control
- Charging rack with closed or perforated trays for loading the furnace in two levels incl. holder for inserting/removing the trays up to a max. temperature of 800 °C and a max. loading weight per layer of 2 kg for the L(T) 9/11 respectively 3 kg for the L(T) 15/11
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions2 in mm | Temperature uniformity of +/− 5K in the empty workspace5 | Connected load | Electrical | Weight | Heating time | |||||||
in °C1 | w | d | h | in l | W | D | H3 | w | d | h | in kW | connection | in kg | in min4 | ||
L(T) 3/11 | 1100 | 160 | 140 | 100 | 3 | 385 | 330 | 405+155 | 110 | 50 | 50 | 1.2 | 1-phase | 21 | 41 | |
L(T) 5/11 | 1100 | 205 | 170 | 130 | 5 | 385 | 390 | 460+205 | 170 | 80 | 80 | 2.4 | 1-phase | 27 | 47 | |
L(T) 9/11 | 1100 | 235 | 240 | 170 | 9 | 415 | 455 | 515+240 | 180 | 150 | 120 | 3.0 | 1-phase | 35 | 63 | |
L(T) 15/11 | 1100 | 230 | 340 | 170 | 15 | 415 | 555 | 515+240 | 180 | 250 | 120 | 3.2 | 1-phase | 43 | 74 | |
L(T) 24/11 | 1100 | 280 | 340 | 250 | 24 | 490 | 555 | 580+320 | 230 | 250 | 200 | 4.5 | 3-phase | 52 | 69 | |
L(T) 40/11 | 1100 | 320 | 490 | 250 | 40 | 530 | 705 | 580+320 | 270 | 400 | 200 | 6.0 | 3-phase | 70 | 80 | |
LT 60/11 | 1100 | 380 | 490 | 330 | 60 | 610 | 705 | 660+385 | 290 | 360 | 240 | 9,1 | 3-phase | 83 | 150 | |
L 1/12 | 1200 | 90 | 115 | 110 | 1 | 290 | 280 | 410 | 40 | 45 | 60 | 1.5 | 1-phase | 15 | 25 | |
L(T) 3/12 | 1200 | 160 | 140 | 100 | 3 | 385 | 330 | 405+155 | 110 | 50 | 50 | 1.2 | 1-phase | 21 | 48 | |
L(T) 5/12 | 1200 | 205 | 170 | 130 | 5 | 385 | 390 | 460+205 | 170 | 80 | 80 | 2.4 | 1-phase | 27 | 59 | |
L(T) 9/12 | 1200 | 235 | 240 | 170 | 9 | 415 | 455 | 515+240 | 180 | 150 | 120 | 3.0 | 1-phase | 35 | 78 | |
L(T) 15/12 | 1200 | 230 | 340 | 170 | 15 | 415 | 555 | 515+240 | 180 | 250 | 120 | 3.2 | 1-phase | 43 | 99 | |
L(T) 24/12 | 1200 | 280 | 340 | 250 | 24 | 490 | 555 | 580+320 | 230 | 250 | 200 | 4.5 | 3-phase | 52 | 82 | |
L(T) 40/12 | 1200 | 320 | 490 | 250 | 40 | 530 | 705 | 580+320 | 270 | 400 | 200 | 6.0 | 3-phase | 70 | 97 | |
LT 60/12 | 1200 | 380 | 490 | 330 | 60 | 610 | 705 | 660+385 | 290 | 360 | 240 | 9,1 | 3-phase | 83 | 160 | |
1. Recommended working temperature for processes with longer dwell times is 1000 °C (L../11) rsp. 1100 °C (L../12) 2. External dimensions vary when furnace is equipped with additional equipment. Dimensions on request. 3. Including opened lift door (LT models) 4. Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE rsp. 400 V 3/N/PE) 5. Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C |
||||||||||||||||
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Related products, Twitter, Instagram, YouTube
Download Catalogue
Muffle Furnaces up to 1100 °C or 1200 °C, L 3/11 – LT 60/12, 1L to 60L
Muffle Furnaces up to 1100 °C or 1200 °C, L 3/11 - LT 60/12, 1L to 60L
The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
- Model: L (T) Series
- Volume: 1L to 60L
- Brand: Nabertherm
- Country of Origin: Germany
- Country of Manufacture: Germany
MUFFLE FURNACES UP TO 1400 °C Nabertherm is one of the world's leading manufacturers of laboratory furnaces based in Lilienthal near Bremen. We probably offer the widest range of muffle furnaces, drying ovens, high-temperature furnaces or tube furnaces.
With more than 70 years of experience and one of the largest engineering departments in the furnace industry, the name Nabertherm stands for high quality "Made in Germany", future-oriented innovations, worldwide service and reliability. More than 100,000 customers in over 100 countries underline this.
Contact us directly, one of our global sales offices or our network of long-term trading partners. We would be happy to advise you so that your research and development will also be a complete success.
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment
- Tmax 1100 °C or 1200 °C
- Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
- Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
- Thermocouple type N (1100 °C) or type S (1200 °C)
- Ceramic heating plates with integral heating element which is safeguarded and easy to replace
- Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
- Dual shell housing made of textured stainless-steel sheets with additional fan cooling for low surface temperature
- Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
- Adjustable air inlet integrated in door (see illustration)
- Exhaust air outlet in rear wall of furnace
- Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
- Solid state relays provide for lownoise operation
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
- have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
- Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
- Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
- Protective gas connection to purge with non-flammable protective or reaction gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
- Manual or automatic gas supply system
- Port for thermocouple in the rear wall or in the furnace door
- Process control and documentation via VCD software package for monitoring, documentation and control
- Charging rack with closed or perforated trays for loading the furnace in two levels incl. holder for inserting/removing the trays up to a max. temperature of 800 °C and a max. loading weight per layer of 2 kg for the L(T) 9/11 respectively 3 kg for the L(T) 15/11
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions2 in mm | Temperature uniformity of +/− 5K in the empty workspace5 | Connected load | Electrical | Weight | Heating time | |||||||
in °C1 | w | d | h | in l | W | D | H3 | w | d | h | in kW | connection | in kg | in min4 | ||
L(T) 3/11 | 1100 | 160 | 140 | 100 | 3 | 385 | 330 | 405+155 | 110 | 50 | 50 | 1.2 | 1-phase | 21 | 41 | |
L(T) 5/11 | 1100 | 205 | 170 | 130 | 5 | 385 | 390 | 460+205 | 170 | 80 | 80 | 2.4 | 1-phase | 27 | 47 | |
L(T) 9/11 | 1100 | 235 | 240 | 170 | 9 | 415 | 455 | 515+240 | 180 | 150 | 120 | 3.0 | 1-phase | 35 | 63 | |
L(T) 15/11 | 1100 | 230 | 340 | 170 | 15 | 415 | 555 | 515+240 | 180 | 250 | 120 | 3.2 | 1-phase | 43 | 74 | |
L(T) 24/11 | 1100 | 280 | 340 | 250 | 24 | 490 | 555 | 580+320 | 230 | 250 | 200 | 4.5 | 3-phase | 52 | 69 | |
L(T) 40/11 | 1100 | 320 | 490 | 250 | 40 | 530 | 705 | 580+320 | 270 | 400 | 200 | 6.0 | 3-phase | 70 | 80 | |
LT 60/11 | 1100 | 380 | 490 | 330 | 60 | 610 | 705 | 660+385 | 290 | 360 | 240 | 9,1 | 3-phase | 83 | 150 | |
L 1/12 | 1200 | 90 | 115 | 110 | 1 | 290 | 280 | 410 | 40 | 45 | 60 | 1.5 | 1-phase | 15 | 25 | |
L(T) 3/12 | 1200 | 160 | 140 | 100 | 3 | 385 | 330 | 405+155 | 110 | 50 | 50 | 1.2 | 1-phase | 21 | 48 | |
L(T) 5/12 | 1200 | 205 | 170 | 130 | 5 | 385 | 390 | 460+205 | 170 | 80 | 80 | 2.4 | 1-phase | 27 | 59 | |
L(T) 9/12 | 1200 | 235 | 240 | 170 | 9 | 415 | 455 | 515+240 | 180 | 150 | 120 | 3.0 | 1-phase | 35 | 78 | |
L(T) 15/12 | 1200 | 230 | 340 | 170 | 15 | 415 | 555 | 515+240 | 180 | 250 | 120 | 3.2 | 1-phase | 43 | 99 | |
L(T) 24/12 | 1200 | 280 | 340 | 250 | 24 | 490 | 555 | 580+320 | 230 | 250 | 200 | 4.5 | 3-phase | 52 | 82 | |
L(T) 40/12 | 1200 | 320 | 490 | 250 | 40 | 530 | 705 | 580+320 | 270 | 400 | 200 | 6.0 | 3-phase | 70 | 97 | |
LT 60/12 | 1200 | 380 | 490 | 330 | 60 | 610 | 705 | 660+385 | 290 | 360 | 240 | 9,1 | 3-phase | 83 | 160 | |
1. Recommended working temperature for processes with longer dwell times is 1000 °C (L../11) rsp. 1100 °C (L../12) 2. External dimensions vary when furnace is equipped with additional equipment. Dimensions on request. 3. Including opened lift door (LT models) 4. Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE rsp. 400 V 3/N/PE) 5. Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C |
||||||||||||||||
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Related products, Twitter, Instagram, YouTube
Download Catalogue
Muffle Furnaces up to 1100 °C or 1200 °C, L 3/11 - LT 60/12, 1L to 60L
Reviews
There are no reviews yet.