Muffle furnace
0.00৳
Muffle furnaces with hinged or lifting door
DEAR USER
We present to your attention Nabertherm muffle furnaces.
Muffle furnaces with hinged or lifting door, 1100°C or 1200°C, L 3/11 & LT 40/12
The Nabertherm L 3/11 – LT 40/12 muffle furnace range is perfect for daily laboratory use. Excellent performance, modern design and a high degree of reliability are the hallmarks of this model range. Muffle furnaces are supplied with a hinged or lifting door.
Muffle furnaces with hinged or lifting door
DEAR USER
We present to your attention Nabertherm muffle furnaces.
Muffle furnaces with hinged or lifting door, 1100°C or 1200°C, L 3/11 & LT 40/12
The Nabertherm L 3/11 - LT 40/12 muffle furnace range is perfect for daily laboratory use. Excellent performance, modern design and a high degree of reliability are the hallmarks of this model range. Muffle furnaces are supplied with a hinged or lifting door.
- Maximum temperature 1100 ° C or 1200 ° C;
- Heating the oven from both sides with ceramic burners (for models L 24/11 - LT 40/12, heating from three sides);
- Ceramic heating plates with an integrated heating element, protected against splashes and fumes (easy to replace);
- Vacuum hardened high strength fiber module;
- Muffle furnace body made of structured stainless steel sheets;
- Double wall muffle furnace body for low external temperatures and high stability;
- Muffle furnaces are available as an option with either a hinged door (L), which can be used as an additional loading and unloading area, or a lifting door (LT), with the hot side facing away from the operator;
- Adjustable intake air opening in the muffle furnace door;
- Exhaust hole in the rear wall of the furnace;
- Quiet operation of the muffle furnace heating system with semiconductor relays.
Additional equipment for muffle furnaces:
- Chimney, chimney with fan or catalytic converter;
- Adjustable temperature limiter with adjustable shutdown temperature for thermal protection class 2 according to EN 60519-2 as overheating protection for ovens and products;
- Shielding gas supply at the rear of the furnace;
- Manual or automatic gas supply system.
Technical data for Nabertherm hinged door muffle furnaces | |||||||||||||||||||
Furnace model | T max , ° C | Internal dimensions, mm | Volume, l | External dimensions, mm | power, kWt | Power supply | Weight, kg | Minutes to T max | |||||||||||
Sh | D | IN | Sh | D | IN | ||||||||||||||
L 3/11 | 1100 | 160 | 140 | 100 | 3 | 380 | 370 | 420 | 1,2 | 1-phase | twenty | 60 | |||||||
L 5/11 | 1100 | 200 | 170 | 130 | 5 | 440 | 470 | 520 | 2.4 | 1-phase | 35 | 60 | |||||||
L 9/11 | 1100 | 230 | 240 | 170 | 9 | 480 | 550 | 570 | 3.0 | 1-phase | 45 | 75 | |||||||
L 15/11 | 1100 | 230 | 340 | 170 | 15 | 480 | 650 | 570 | 3.6 | 1-phase | 55 | 90 | |||||||
L 24/11 | 1100 | 280 | 340 | 250 | 24 | 560 | 660 | 650 | 4.5 | 3-phase | 75 | 95 | |||||||
L 40/11 | 1100 | 320 | 490 | 250 | 40 | 600 | 790 | 650 | 6.0 | 3-phase | 95 | 95 | |||||||
L 3/12 | 1200 | 160 | 140 | 100 | 3 | 380 | 370 | 420 | 1,2 | 1-phase | twenty | 75 | |||||||
L 5/12 | 1200 | 200 | 170 | 130 | 5 | 440 | 470 | 520 | 2.4 | 1-phase | 35 | 75 | |||||||
L 9/12 | 1200 | 230 | 240 | 170 | 9 | 480 | 550 | 570 | 3.0 | 1-phase | 45 | 90 | |||||||
L 15/12 | 1200 | 230 | 340 | 170 | 15 | 480 | 650 | 570 | 3.6 | 1-phase | 55 | 105 | |||||||
L 24/12 | 1200 | 280 | 340 | 250 | 24 | 560 | 660 | 650 | 4.5 | 3-phase | 75 | 110 | |||||||
L 40/12 | 1200 | 320 | 490 | 250 | 40 | 600 | 790 | 650 | 6.0 | 3-phase | 95 | 100 | |||||||
Technical Data for Nabertherm Lift Door Muffle Furnaces | |||||||||||||||||||
Furnace model | T max , ° C | Internal dimensions, mm | Volume, l | External dimensions, mm | power, kWt | Power supply | Weight, kg | Minutes to T max | |||||||||||
Sh | D | IN | Sh | D | IN* | ||||||||||||||
LT 3/11 | 1100 | 160 | 140 | 100 | 3 | 380 | 370 | 420 + 165 | 1,2 | 1-phase | twenty | 60 | |||||||
LT 5/11 | 1100 | 200 | 170 | 130 | 5 | 440 | 470 | 520 + 220 | 2.4 | 1-phase | 35 | 60 | |||||||
LT 9/11 | 1100 | 230 | 240 | 170 | 9 | 480 | 550 | 570 + 290 | 3.0 | 1-phase | 45 | 75 | |||||||
LT 15/11 | 1100 | 230 | 340 | 170 | 15 | 480 | 650 | 570 + 290 | 3.6 | 1-phase | 55 | 90 | |||||||
LT 24/11 | 1100 | 280 | 340 | 250 | 24 | 560 | 660 | 650 + 335 | 4.5 | 3-phase | 75 | 95 | |||||||
LT 40/11 | 1100 | 320 | 490 | 250 | 40 | 600 | 790 | 650 + 335 | 6.0 | 3-phase | 95 | 95 | |||||||
LT 3/12 | 1200 | 160 | 140 | 100 | 3 | 380 | 370 | 420 + 165 | 1,2 | 1-phase | twenty | 75 | |||||||
LT 5/12 | 1200 | 200 | 170 | 130 | 5 | 440 | 470 | 520 + 220 | 2.4 | 1-phase | 35 | 75 | |||||||
LT 9/12 | 1200 | 230 | 240 | 170 | 9 | 480 | 550 | 570 + 290 | 3.0 | 1-phase | 45 | 90 | |||||||
LT 15/12 | 1200 | 230 | 340 | 170 | 15 | 480 | 650 | 570 + 290 | 3.6 | 1-phase | 55 | 105 | |||||||
LT 24/12 | 1200 | 280 | 340 | 250 | 24 | 560 | 660 | 650 + 335 | 4.5 | 3-phase | 75 | 110 | |||||||
LT 40/12 | 1200 | 320 | 490 | 250 | 40 | 600 | 790 | 650 + 335 | 6.0 | 3-phase | 95 | 100 | |||||||
* incl. open lift door |
Controller B410
- Easy to install the program
- Black and white LC screen, high contrast
- Display text messages (2 lines)
- Input data with 4 keys (on/off/pause, menu, back, info)
- Stores 5 programs, each program can be adjusted in 4 steps
- Step of temperature adjustment 1 o C
- Accuracy ± 1°C
- Choice of °C/°F
- Display on the menu parameters:
- Working timer
- Count kWh
- Show error history
- Output of control values
- Auto-optimization feature
- Calibration of measuring range with selection of up to 10 points
- NTLog USB port for data retrieval and processing
- In case of power failure, the following modes can be selected:
- Automatically resume running according to the program right before the power failure
- Automatically continue running according to the program right before the power failure if the power failure time is < 2 minutes, if more than that, do not continue running.
- Automatically continue running according to the program right before the power failure if the temperature does not drop lower than 50oC, if it is lower, do not continue running
- Do not continue to run the old program when restoring the power
- Language selection: 17 kinds of languages (English / French / German / Italian...)
- Supplier in Bangladesh- Elite Scientific & Meditech Co.
- For any queries visit us- www.elitetradebd.com
Reviews