Leakage Current Clamp Meter 368 FC
0.00৳
Fluke 368 FC Leakage Current Clamp Meter
- Brand: Fluke
- Branch: Industrial Grade
- Category: Clamp Meters
- Model: Fluke 368 FC Leakage Current Clamp Meter
Measure Fluke 368 FC Leakage Current Clamp Meter to track small problems, avoid large problems. The Fluke 360 Series of true-rms escape current clamp meters help users find, document, record and compare escape the current. Readings over time as a method of preventing unplanned period, and distinctive intermittent GFCI and RCD journeys, without taking equipment offline.
The Fluke 368 FC and 369 FC have giant diameter jaws (40 millimeters for the 368 FC, 61 mm for the 369 FC) for work with larger conductors. The clamp’s jaw is absolutely secure to accurately capture terribly small leakage signals and to minimize external electromagnetic interference.
The 368 FC and 369 FC additionally provide wireless knowledge property via Fluke Connect. As part of Fluke Connect—the industry’s largest system of code and over forty wireless check tools—the 368 FC and 369 FC permit you to trace changes in escape current over time, serving to spot potential issues before they flip into major failures.
Features
Key Features: Fluke 368 FC Leakage Current Clamp Meter
- Backlit display; auto backlight off and auto power off for extended battery life
- True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms
- 40 mm jaw opening
- Selectable filter function removes unwanted noise
- Highest resolution of 1 μA, measure up to 60 A
- Max/Min/Average readings and hold function
- Forward-facing LED work light for use in dark wiring cabinets
- CAT III 600V safety rating
- Internal Memory Logging: up to 65,000 measurement points
Specifications: Fluke 368 FC Leakage Current Clamp Meter
Electrical Specifications | ||
Measurement function | Alternating current | |
AC ampere range | 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A | |
mA / A: manual selection 3 mA / 30 mA / 300 mA: automatic selection 3 A / 30 A / 60 A: automatic selection |
||
Range / Resolution | 3 mA¹ / 0.001 mA | |
30 mA / 0.01 mA | ||
300 mA / 0.1 mA | ||
3 A / 0.001 A | ||
30 A / 0.01 A | ||
60 A / 0.1 A | ||
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)² | 3 mA – 30 A 60 A |
1% + 5 digits 2% + 5 digits |
Frequency | 40 Hz to 1 kHz | |
Crest Factor | 3 | |
After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%. ¹The minimum value is 10 μA rms. ²Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1 |
||
Physical | ||
Display (LCD) | Digital readout: 3300 count | |
Display refresh rate | 4 times / sec | |
Maximum conductor diameter | 40 mm | |
Dimensions | 234 x 101 x 46 mm | |
Weight | 500 g | |
Battery | 2 AA, IEC LR6, NEDA 15A, alkaline | |
Battery life | Expected battery life, without using backlight and spotlight, is more than 150 hours | |
Automatic shut-down | Meter automatically shuts down after 15 minutes of inactivity | |
Safety and Environmental Specifications | ||
General safety | IEC 61010-1: Pollution Degree 2 | |
Measurement safety | IEC 61010-2-032: CAT III 600 V / CAT IV 300 V | |
Operating temperature | -10 °C to +50 °C | |
Storage temperature | -40 °C to +60 °C | |
Operating humidity | Non-condensing (<10 °C) | |
90% relative humidity (10 °C to 30 °C) | ||
75% relative humidity (30 °C to 40 °C) | ||
45% relative humidity (40 °C to 50 °C) | ||
Protection class | IEC 60529: IP30 (jaw closed) | |
Operating altitude | 2000 m | |
Storage altitude | 12000 m | |
Current sensor action category | IEC 61557-13: Class 2, ≤30 A / m | |
Electromagnetic compatibility (EMC) | ||
International | ||
IEC 61326-1 | Industrial Electromagnetic Environment | |
CISPR 11 | Group 1 Class B | |
Group 1 | Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device’s own internal functions is essential. | |
Class B | Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements. Korea (KCC): A type of equipment (radio and communication equipment industry) |
|
Class A | This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment. USA (FCC): 47 CFR 15 B Subpart. In accordance with section 15.103 provides that the products are considered tax-free device. |
Includes
Includes: Fluke 368 FC Leakage Current Clamp Meter
Includes:
- Leakage Clamp Meter
- Soft case
- Batteries: 2 AA
- Safety manual
Accessories
- Accessories: Fluke 368 FC Leakage Current Clamp Meter
- Fluke 368 has a large 40 mm diameter jaw for work with large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals and to minimize external electromagnetic interference
Others related Meter
- Fluke 368 FC Leakage Current Clamp Meter
- Fluke 353 True RMS 2000 A Clamp Meter
- Fluke 302 Plus Clamp Meter
- Fluke 323 True RMS Clamp Meter
- Fluke 325 True RMS Clamp Meter
- Fluke 365 Detachable Jaw True RMS AC/DC…
- Fluke 355 True RMS 2000 A Clamp Meter
- Fluke 773 Milliamp Process Clamp Meter
- Fluke 375 True RMS AC/DC Clamp Meter
- Fluke 772 Milliamp Clamp Meter
- Fluke a3001 FC Wireless iFlex® AC Curren…
- Fluke 381 Remote Display True RMS AC/DC…
- Fluke 373 True-RMS AC Clamp Meter
- Fluke 376 True RMS AC/DC Clamp Meter
- Fluke 303 Clamp Meter
- Fluke 305 Clamp Meter
- Fluke 317 Clamp Meter
- Fluke 319 Clamp Meter
- Fluke 902 FC True-RMS HVAC Clamp Meter
OTHERS LINKS
- Reseller in BD : Elite Scientific & Meditech Co
- Web address : www.elitetradebd.com
- Twitter : https://twitter.com/elitetradebd
- Face book : https://www.facebook.com/elitetradebd
- Instagram : https://www.instagram.com/elitetradebd/
- LinkedIn : https://www.linkedin.com/in/elitetradebd/#
Fluke 368 FC Leakage Current Clamp Meter
- Brand: Fluke
- Branch: Industrial Grade
- Category: Clamp Meters
- Model: Fluke 368 FC Leakage Current Clamp Meter
Measure Fluke 368 FC Leakage Current Clamp Meter to track small problems, avoid large problems. The Fluke 360 Series of true-rms escape current clamp meters help users find, document, record and compare escape the current. Readings over time as a method of preventing unplanned period, and distinctive intermittent GFCI and RCD journeys, without taking equipment offline.
The Fluke 368 FC and 369 FC have giant diameter jaws (40 millimeters for the 368 FC, 61 mm for the 369 FC) for work with larger conductors. The clamp’s jaw is absolutely secure to accurately capture terribly small leakage signals and to minimize external electromagnetic interference.
The 368 FC and 369 FC additionally provide wireless knowledge property via Fluke Connect. As part of Fluke Connect—the industry’s largest system of code and over forty wireless check tools—the 368 FC and 369 FC permit you to trace changes in escape current over time, serving to spot potential issues before they flip into major failures.
Features
Key Features: Fluke 368 FC Leakage Current Clamp Meter
- Backlit display; auto backlight off and auto power off for extended battery life
- True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms
- 40 mm jaw opening
- Selectable filter function removes unwanted noise
- Highest resolution of 1 μA, measure up to 60 A
- Max/Min/Average readings and hold function
- Forward-facing LED work light for use in dark wiring cabinets
- CAT III 600V safety rating
- Internal Memory Logging: up to 65,000 measurement points
Specifications: Fluke 368 FC Leakage Current Clamp Meter
Electrical Specifications | ||
Measurement function | Alternating current | |
AC ampere range | 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A | |
mA / A: manual selection 3 mA / 30 mA / 300 mA: automatic selection 3 A / 30 A / 60 A: automatic selection |
||
Range / Resolution | 3 mA¹ / 0.001 mA | |
30 mA / 0.01 mA | ||
300 mA / 0.1 mA | ||
3 A / 0.001 A | ||
30 A / 0.01 A | ||
60 A / 0.1 A | ||
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)² | 3 mA – 30 A 60 A |
1% + 5 digits 2% + 5 digits |
Frequency | 40 Hz to 1 kHz | |
Crest Factor | 3 | |
After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%. ¹The minimum value is 10 μA rms. ²Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1 |
||
Physical | ||
Display (LCD) | Digital readout: 3300 count | |
Display refresh rate | 4 times / sec | |
Maximum conductor diameter | 40 mm | |
Dimensions | 234 x 101 x 46 mm | |
Weight | 500 g | |
Battery | 2 AA, IEC LR6, NEDA 15A, alkaline | |
Battery life | Expected battery life, without using backlight and spotlight, is more than 150 hours | |
Automatic shut-down | Meter automatically shuts down after 15 minutes of inactivity | |
Safety and Environmental Specifications | ||
General safety | IEC 61010-1: Pollution Degree 2 | |
Measurement safety | IEC 61010-2-032: CAT III 600 V / CAT IV 300 V | |
Operating temperature | -10 °C to +50 °C | |
Storage temperature | -40 °C to +60 °C | |
Operating humidity | Non-condensing (<10 °C) | |
90% relative humidity (10 °C to 30 °C) | ||
75% relative humidity (30 °C to 40 °C) | ||
45% relative humidity (40 °C to 50 °C) | ||
Protection class | IEC 60529: IP30 (jaw closed) | |
Operating altitude | 2000 m | |
Storage altitude | 12000 m | |
Current sensor action category | IEC 61557-13: Class 2, ≤30 A / m | |
Electromagnetic compatibility (EMC) | ||
International | ||
IEC 61326-1 | Industrial Electromagnetic Environment | |
CISPR 11 | Group 1 Class B | |
Group 1 | Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential. | |
Class B | Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements. Korea (KCC): A type of equipment (radio and communication equipment industry) |
|
Class A | This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment. USA (FCC): 47 CFR 15 B Subpart. In accordance with section 15.103 provides that the products are considered tax-free device. |
Includes
Includes: Fluke 368 FC Leakage Current Clamp Meter
Includes:
- Leakage Clamp Meter
- Soft case
- Batteries: 2 AA
- Safety manual
Accessories
- Accessories: Fluke 368 FC Leakage Current Clamp Meter
- Fluke 368 has a large 40 mm diameter jaw for work with large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals and to minimize external electromagnetic interference
Others related Meter
- Fluke 368 FC Leakage Current Clamp Meter
- Fluke 353 True RMS 2000 A Clamp Meter
- Fluke 302 Plus Clamp Meter
- Fluke 323 True RMS Clamp Meter
- Fluke 325 True RMS Clamp Meter
- Fluke 365 Detachable Jaw True RMS AC/DC...
- Fluke 355 True RMS 2000 A Clamp Meter
- Fluke 773 Milliamp Process Clamp Meter
- Fluke 375 True RMS AC/DC Clamp Meter
- Fluke 772 Milliamp Clamp Meter
- Fluke a3001 FC Wireless iFlex® AC Curren...
- Fluke 381 Remote Display True RMS AC/DC...
- Fluke 373 True-RMS AC Clamp Meter
- Fluke 376 True RMS AC/DC Clamp Meter
- Fluke 303 Clamp Meter
- Fluke 305 Clamp Meter
- Fluke 317 Clamp Meter
- Fluke 319 Clamp Meter
- Fluke 902 FC True-RMS HVAC Clamp Meter
OTHERS LINKS
- Reseller in BD : Elite Scientific & Meditech Co
- Web address : www.elitetradebd.com
- Twitter : https://twitter.com/elitetradebd
- Face book : https://www.facebook.com/elitetradebd
- Instagram : https://www.instagram.com/elitetradebd/
- LinkedIn : https://www.linkedin.com/in/elitetradebd/#
Reviews
There are no reviews yet.