Fluke 2000 A Clamp Meter 355 True RMS
0.00৳
Fluke 355 True RMS 2000 A Clamp Meter
- Brand: Fluke
- Branch: Industrial Grade
- Category: Clamp Meters
Model: Fluke 355 True RMS 2000 A Clamp Meter
Fluke 355 True RMS 2000 A Clamp Meter accurately measures frequency up to 1 kHz for optimum troubleshooting.
Versatile and rugged tools for applications with high currents.
Confidently take reliable readings with verity RMS, Fluke 355 digital clamp meter the tool of selection for prime current clamp-on amp meter measure up to 2000 A. The extra-wide jaw simply clamps around giant conductors, generally found in high-current applications. the additional rugged style and CAT IV 600 V, CAT III a thousand V ratings add an additional part of user protection once taking high-powered measurements.
Accurate peak measurements may be taken victimization the in-rush current mode, ideal for motors and inductive masses. The 355 additionally measures voltage and resistance, creating this a perfect clamp meter for utilities, electrical contractors, and industrial service engineers.
Key features: Fluke 355 True RMS 2000 A Clamp Meter
- Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC
- The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
- CAT IV 600 V, CAT III 1000 V rating for added user protection
- In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
- High voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool
- Resistance to 400K ohms coupled with a continuity beeper provides the convenience of a multimeter in a clamp meter.
- Accurately measure frequency up to 1 kHz for optimum troubleshooting
- Quickly analyze readings using the MIN, MAX, and AVG functions
- A large backlit display allows for easy visibility in low-lit areas
- Use the display hold feature to capture readings even when the display cannot be viewed
- Use the low-pass filter to smooth out noisy loads and stabilize readings
Specifications: Fluke 355 True RMS 2000 A Clamp Meter
Electrical Specifications | ||||
Current measurement DC and AC 10 Hz to 100 Hz | Range | 40 A / 400 A / 2000 A / 1400 AC rms | ||
Resolution | 10 mA / 100 mA / 1 A | |||
Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
|||
Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |||
Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |||
Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |||
Crest Factor (50/60 Hz) | Range | 40 A / 400 A / 2000 A / 1400 AC rms | ||
Crest Factor1 | 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A |
|||
Current measurement AC 100.1 Hz to 1 kHz | Range | 40 A / 400 A / 2000 A; 1400 AC rms | ||
Resolution | 10 mA / 100 mA / 1 A | |||
Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
|||
Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |||
Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |||
Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |||
Voltage measurement DC and AC 10 Hz to 100 Hz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) |
Range | 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC | ||
Resolution | 1 mV / 10 mV / 100 mV / 1 V | |||
Accuracy | 1% rdg + 10 digits 1% rdg + 5 digits |
|||
Trigger level for Hz filter OFF | 0.25 V / 6 V | |||
Trigger level for Hz filter ON | 0.25 V / 6 V | |||
Voltage measurement AC 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) |
Range | 4 V / 40 V / 400 V / 600 V ac rms | ||
Resolution | 1 mV / 10 mV / 100 mV / 1 V | |||
Accuracy | 3% rdg + 10 digits 3% rdg + 5 digits |
|||
Trigger level for Hz filter OFF | 0.050 V / 0.25 V / 6 V | |||
Trigger level for Hz filter ON | 0.050 V / 0.25 V / 6 V | |||
Ohms measurement | Range | 4 kΩ / 40 kΩ / 400 kΩ | ||
Resolution | 0.1 Ω / 1 Ω / 10 Ω / 100 Ω | |||
Accuracy | 1.5% + 5 digits | |||
Continuity beeper | On at ≤ 30 Ω Off at ≥ 100 Ω |
|||
Frequency measurement | Measurement range | 5.0 Hz to 1 kHz | ||
Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | |||
Accuracy – 5.0 Hz to 100 Hz | 0.2% + 2 counts | |||
Accuracy – 100.1 Hz to 1 kHz | 0.5% + 5 counts | |||
Trigger level | Refer to current and voltage tables | |||
1. Add 2% to error spec for CF > 2 | ||||
General Specifications | ||||
Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 | |||
Battery life (with typical usage, backlight off) | 100 hours | |||
Test leads | Rated to 1000 V | |||
Weight | .814 kg (1.8 lb) | |||
Jaw size | 58 mm (2.28 in) | |||
Dimensions (L x W x D) | 300 x 98 x 52 mm (12 x 3.75 x 2 in) | |||
Safety rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III | |||
Environmental Specifications | ||||
Operating temperature | 32°F to +122°F (0°C to +50°C) | |||
Storage temperature | -4°F to 140°F (-20°C to +60°C) | |||
Operating humidity | 0 to 95% (non-condensing) | |||
Operating altitude | 2000 m | |||
Storage altitude | 10,000 m | |||
IP rating | 42 (indoor use only) | |||
Drop test requirements | 1 m | |||
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325 |
|||
Temperature coefficients | Current | 0.1% of reading per °C outside 22°C to 24°C | ||
Voltage | 0.1% of reading per °C outside 22°C to 24°C | |||
Fluke 355Fluke 355 True RMS 2000 A Clamp Meter
Includes:
- C43 soft carrying case
- 6 AA batteries
- TL224 1.5 m silicone rubber test leads
- AC285 alligator clips
- User manual
- TP2 test probes
- 3-year warranty
Others related Meter
- Fluke 368 FC Leakage Current Clamp Meter
- Fluke 353 True RMS 2000 A Clamp Meter
- Fluke 302 Plus Clamp Meter
- Fluke 323 True RMS Clamp Meter
- Fluke 325 True RMS Clamp Meter
- Fluke 365 Detachable Jaw True RMS AC/DC…
- Fluke 355 True RMS 2000 A Clamp Meter
- Fluke 773 Milliamp Process Clamp Meter
- Fluke 375 True RMS AC/DC Clamp Meter
- Fluke 772 Milliamp Clamp Meter
- Fluke a3001 FC Wireless iFlex® AC Curren…
- Fluke 381 Remote Display True RMS AC/DC…
- Fluke 373 True-RMS AC Clamp Meter
- Fluke 376 True RMS AC/DC Clamp Meter
- Fluke 303 Clamp Meter
- Fluke 305 Clamp Meter
- Fluke 317 Clamp Meter
- Fluke 319 Clamp Meter
- Fluke 902 FC True-RMS HVAC Clamp Meter
OTHERS Social LINKS
- Reseller in BD : Elite Scientific & Meditech Co
- Web address : www.elitetradebd.com
- Twitter : https://twitter.com/elitetradebd
- Face book : https://www.facebook.com/elitetradebd
- Instagram : https://www.instagram.com/elitetradebd/
- LinkedIn : https://www.linkedin.com/in/elitetradebd/#
Fluke 355 True RMS 2000 A Clamp Meter
- Brand: Fluke
- Branch: Industrial Grade
- Category: Clamp Meters
Model: Fluke 355 True RMS 2000 A Clamp Meter
Fluke 355 True RMS 2000 A Clamp Meter accurately measures frequency up to 1 kHz for optimum troubleshooting.
Versatile and rugged tools for applications with high currents.
Confidently take reliable readings with verity RMS, Fluke 355 digital clamp meter the tool of selection for prime current clamp-on amp meter measure up to 2000 A. The extra-wide jaw simply clamps around giant conductors, generally found in high-current applications. the additional rugged style and CAT IV 600 V, CAT III a thousand V ratings add an additional part of user protection once taking high-powered measurements.
Accurate peak measurements may be taken victimization the in-rush current mode, ideal for motors and inductive masses. The 355 additionally measures voltage and resistance, creating this a perfect clamp meter for utilities, electrical contractors, and industrial service engineers.
Key features: Fluke 355 True RMS 2000 A Clamp Meter
- Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC
- The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
- CAT IV 600 V, CAT III 1000 V rating for added user protection
- In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
- High voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool
- Resistance to 400K ohms coupled with a continuity beeper provides the convenience of a multimeter in a clamp meter.
- Accurately measure frequency up to 1 kHz for optimum troubleshooting
- Quickly analyze readings using the MIN, MAX, and AVG functions
- A large backlit display allows for easy visibility in low-lit areas
- Use the display hold feature to capture readings even when the display cannot be viewed
- Use the low-pass filter to smooth out noisy loads and stabilize readings
Specifications: Fluke 355 True RMS 2000 A Clamp Meter
Electrical Specifications | ||||
Current measurement DC and AC 10 Hz to 100 Hz | Range | 40 A / 400 A / 2000 A / 1400 AC rms | ||
Resolution | 10 mA / 100 mA / 1 A | |||
Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
|||
Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |||
Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |||
Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |||
Crest Factor (50/60 Hz) | Range | 40 A / 400 A / 2000 A / 1400 AC rms | ||
Crest Factor1 | 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A |
|||
Current measurement AC 100.1 Hz to 1 kHz | Range | 40 A / 400 A / 2000 A; 1400 AC rms | ||
Resolution | 10 mA / 100 mA / 1 A | |||
Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
|||
Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |||
Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |||
Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |||
Voltage measurement DC and AC 10 Hz to 100 Hz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) |
Range | 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC | ||
Resolution | 1 mV / 10 mV / 100 mV / 1 V | |||
Accuracy | 1% rdg + 10 digits 1% rdg + 5 digits |
|||
Trigger level for Hz filter OFF | 0.25 V / 6 V | |||
Trigger level for Hz filter ON | 0.25 V / 6 V | |||
Voltage measurement AC 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) |
Range | 4 V / 40 V / 400 V / 600 V ac rms | ||
Resolution | 1 mV / 10 mV / 100 mV / 1 V | |||
Accuracy | 3% rdg + 10 digits 3% rdg + 5 digits |
|||
Trigger level for Hz filter OFF | 0.050 V / 0.25 V / 6 V | |||
Trigger level for Hz filter ON | 0.050 V / 0.25 V / 6 V | |||
Ohms measurement | Range | 4 kΩ / 40 kΩ / 400 kΩ | ||
Resolution | 0.1 Ω / 1 Ω / 10 Ω / 100 Ω | |||
Accuracy | 1.5% + 5 digits | |||
Continuity beeper | On at ≤ 30 Ω Off at ≥ 100 Ω |
|||
Frequency measurement | Measurement range | 5.0 Hz to 1 kHz | ||
Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | |||
Accuracy – 5.0 Hz to 100 Hz | 0.2% + 2 counts | |||
Accuracy – 100.1 Hz to 1 kHz | 0.5% + 5 counts | |||
Trigger level | Refer to current and voltage tables | |||
1. Add 2% to error spec for CF > 2 | ||||
General Specifications | ||||
Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 | |||
Battery life (with typical usage, backlight off) | 100 hours | |||
Test leads | Rated to 1000 V | |||
Weight | .814 kg (1.8 lb) | |||
Jaw size | 58 mm (2.28 in) | |||
Dimensions (L x W x D) | 300 x 98 x 52 mm (12 x 3.75 x 2 in) | |||
Safety rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III | |||
Environmental Specifications | ||||
Operating temperature | 32°F to +122°F (0°C to +50°C) | |||
Storage temperature | -4°F to 140°F (-20°C to +60°C) | |||
Operating humidity | 0 to 95% (non-condensing) | |||
Operating altitude | 2000 m | |||
Storage altitude | 10,000 m | |||
IP rating | 42 (indoor use only) | |||
Drop test requirements | 1 m | |||
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325 |
|||
Temperature coefficients | Current | 0.1% of reading per °C outside 22°C to 24°C | ||
Voltage | 0.1% of reading per °C outside 22°C to 24°C | |||
Fluke 355Fluke 355 True RMS 2000 A Clamp Meter
Includes:
- C43 soft carrying case
- 6 AA batteries
- TL224 1.5 m silicone rubber test leads
- AC285 alligator clips
- User manual
- TP2 test probes
- 3-year warranty
Others related Meter
- Fluke 368 FC Leakage Current Clamp Meter
- Fluke 353 True RMS 2000 A Clamp Meter
- Fluke 302 Plus Clamp Meter
- Fluke 323 True RMS Clamp Meter
- Fluke 325 True RMS Clamp Meter
- Fluke 365 Detachable Jaw True RMS AC/DC...
- Fluke 355 True RMS 2000 A Clamp Meter
- Fluke 773 Milliamp Process Clamp Meter
- Fluke 375 True RMS AC/DC Clamp Meter
- Fluke 772 Milliamp Clamp Meter
- Fluke a3001 FC Wireless iFlex® AC Curren...
- Fluke 381 Remote Display True RMS AC/DC...
- Fluke 373 True-RMS AC Clamp Meter
- Fluke 376 True RMS AC/DC Clamp Meter
- Fluke 303 Clamp Meter
- Fluke 305 Clamp Meter
- Fluke 317 Clamp Meter
- Fluke 319 Clamp Meter
- Fluke 902 FC True-RMS HVAC Clamp Meter
OTHERS Social LINKS
- Reseller in BD : Elite Scientific & Meditech Co
- Web address : www.elitetradebd.com
- Twitter : https://twitter.com/elitetradebd
- Face book : https://www.facebook.com/elitetradebd
- Instagram : https://www.instagram.com/elitetradebd/
- LinkedIn : https://www.linkedin.com/in/elitetradebd/#
Reviews