Electrical Tester Fluke T6-600

0.00৳ 

Fluke T6-600 Electrical Tester
  • Brand: Fluke
  • Branch: Industrial Grade
  • Category: Electrical Testers

Model: Fluke T6-600 Electrical Tester

Fluke T6-600 Electrical Tester field sense technology for ac voltage, current, and frequency measurement without making electrical contact to live voltage. The most important things about the Fluke T6-600 electrical tester that always provide an accurate measurement in any environment.

You can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.

Key features: Fluke T6-600 Electrical Tester

5 reasons the T6 belongs in your toolbelt

  1. Be safer: Measure voltage to 600 V ac through the open fork, without test leads.
  2. Be faster: No need to open covers or remove wire nuts.
  3. Be more efficient: Simultaneously measure voltage and current.
  4. Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).
  5. Go beyond simple detection. Actually, measure ac voltage and current values without test leads.

Product Highlights

  • FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage*
  • See voltage or current display – shows all power supply measurements at a glance for efficient troubleshooting
  • 1 to 600 V ac or dc (T6-600)
  • 0 to 200 A ac
  • True-rms voltage and current
  • Resistance 1 Ω to 100 kΩ
  • Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
  • HOLD button temporarily freezes the reading for easy viewing
  • Easy to read display with backlight
  • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
  • Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase+

Tips: FieldSense Technology

Do not hold or touch wire you are testing during a measurement. Use the black probe to make the ground connection if:

  • wearing gloves or insulated footwear
  • standing on an insulated ladder
  • additional ground contact is required for the application

FieldSense measurement looks like this when properly grounded:

  • Display color turns green
  • Display shows a valid measurement >16 V rather than dashes or 0.0
  • shows for measurement ≥30 V

Specifications: Fluke T6-600 Electrical Tester

Measurement Specifications
Function Requires test leads Range Resolution Accuracy[1]
FieldSense
ac voltage true-RMS
No 600 V 1 V ±(3% + 3 counts) 45 Hz – 66 Hz[2] [3]
FieldSense
ac current true-RMS
No 200.0 A 0.1 A ±(3% + 3 counts) 45 Hz – 66 Hz
FieldSense
frequency (Hz)
No 1 Hz ±(1% + 2 counts)[3]
Volts ac true-rms Yes 600 V 1 V ±(1.5% + 2 counts) 45 Hz – 66 Hz
Volts dc Yes 600 V 1 V ±(1% + 2 counts)
Resistance Yes 2000 Ω 1 Ω ±(1% + 2 counts)
Safety 600 V CAT III
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.

Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.

Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

General Specifications
Calibration 1-year calibration cycle
Dimensions 61.1 x 259.3 x 43.8 mm
Jaw opening 17.8 mm
Weight 0.35 kg (0.78 lb)
Temperature Operating -10 °C to +50 °C (14 °F to 122 °F)
Storage -30 °C to +60 °C (-22 °F to +140 °F)
Altitude Operating 2,000 m (6,562 feet)
Storage 10,000 m (32,808 feet)
Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
(< 64.4 °F or > 82.4 °F)
Safety IEC/EN 61010-1: Pollution Degree 2
Electromagnetic Environment IEC/EN 61326-1: Portable

Includes: Fluke T6-600 Electrical Tester

Includes:

  • Attached test leads with removable 4 mm probe caps, user documentation

Others related Meter

  • Fluke T6-1000 Electrical Tester
  • Fluke T6-600 Electrical Tester
  • Fluke T5-1000 Voltage, Continuity and Current Tester
  • Fluke T5-1000 Voltage, Continuity and Current Tester
  • Fluke 1AC II VoltAlert™ Electrical Tester
  • Fluke 2AC VoltAlert™ Electrical Tester
  • Fluke LVD2 Non-Contact Electrical Voltage Tester

OTHERS Social LINKS

Fluke T6-600 Electrical Tester
  • Brand: Fluke
  • Branch: Industrial Grade
  • Category: Electrical Testers

Model: Fluke T6-600 Electrical Tester

Fluke T6-600 Electrical Tester field sense technology for ac voltage, current, and frequency measurement without making electrical contact to live voltage. The most important things about the Fluke T6-600 electrical tester that always provide an accurate measurement in any environment.

You can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.

Key features: Fluke T6-600 Electrical Tester

5 reasons the T6 belongs in your toolbelt

  1. Be safer: Measure voltage to 600 V ac through the open fork, without test leads.
  2. Be faster: No need to open covers or remove wire nuts.
  3. Be more efficient: Simultaneously measure voltage and current.
  4. Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).
  5. Go beyond simple detection. Actually, measure ac voltage and current values without test leads.

Product Highlights

  • FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage*
  • See voltage or current display – shows all power supply measurements at a glance for efficient troubleshooting
  • 1 to 600 V ac or dc (T6-600)
  • 0 to 200 A ac
  • True-rms voltage and current
  • Resistance 1 Ω to 100 kΩ
  • Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
  • HOLD button temporarily freezes the reading for easy viewing
  • Easy to read display with backlight
  • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
  • Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase+

Tips: FieldSense Technology

Do not hold or touch wire you are testing during a measurement. Use the black probe to make the ground connection if:

  • wearing gloves or insulated footwear
  • standing on an insulated ladder
  • additional ground contact is required for the application

FieldSense measurement looks like this when properly grounded:

  • Display color turns green
  • Display shows a valid measurement >16 V rather than dashes or 0.0
  • shows for measurement ≥30 V

Specifications: Fluke T6-600 Electrical Tester

Measurement Specifications
Function Requires test leads Range Resolution Accuracy[1]
FieldSense
ac voltage true-RMS
No 600 V 1 V ±(3% + 3 counts) 45 Hz - 66 Hz[2] [3]
FieldSense
ac current true-RMS
No 200.0 A 0.1 A ±(3% + 3 counts) 45 Hz - 66 Hz
FieldSense
frequency (Hz)
No 1 Hz ±(1% + 2 counts)[3]
Volts ac true-rms Yes 600 V 1 V ±(1.5% + 2 counts) 45 Hz - 66 Hz
Volts dc Yes 600 V 1 V ±(1% + 2 counts)
Resistance Yes 2000 Ω 1 Ω ±(1% + 2 counts)
Safety 600 V CAT III
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.

Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.

Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

General Specifications
Calibration 1-year calibration cycle
Dimensions 61.1 x 259.3 x 43.8 mm
Jaw opening 17.8 mm
Weight 0.35 kg (0.78 lb)
Temperature Operating -10 °C to +50 °C (14 °F to 122 °F)
Storage -30 °C to +60 °C (-22 °F to +140 °F)
Altitude Operating 2,000 m (6,562 feet)
Storage 10,000 m (32,808 feet)
Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
(< 64.4 °F or > 82.4 °F)
Safety IEC/EN 61010-1: Pollution Degree 2
Electromagnetic Environment IEC/EN 61326-1: Portable

Includes: Fluke T6-600 Electrical Tester

Includes:

  • Attached test leads with removable 4 mm probe caps, user documentation

Others related Meter

  • Fluke T6-1000 Electrical Tester
  • Fluke T6-600 Electrical Tester
  • Fluke T5-1000 Voltage, Continuity and Current Tester
  • Fluke T5-1000 Voltage, Continuity and Current Tester
  • Fluke 1AC II VoltAlert™ Electrical Tester
  • Fluke 2AC VoltAlert™ Electrical Tester
  • Fluke LVD2 Non-Contact Electrical Voltage Tester