Bitumen extractor _ electrically operated

0.00৳ 

Introduction

The Centrifuge Extractors are used for determination of bitumen percentage in hot mixed paving mixtures and pavement samples. The mix is added with a solvent and dissolved bitumen is removed by centrifugal action. The Extractors are available in two versions, Hand operated and motorised electrically driven.

General Description & Specification

Hand driven

The Centrifuge Extractor comprises of a precision machine rotor bowl and bowl cover housed in a cylindrical aluminum box. A knurled nut is provided to press filter paper disc between the rotor bowl and cover plate and the complete bowl assembly is removable for determination of weight of sample. The bowl assembly is mounted on a vertical shaft, which comes out from a casted housing. The shaft attached to the bowl is rotated manually by a handle. The gears operate in a casted housing in oil bath with splash lubrication. A drain is provided to collect dissolved bitumen coming out from the rotating bowl. The range of speed is 2400 – 3600 RPM. The bowl capacity is 1.5 Liter

Motorised electrically driven

The motorised version is provided with a variable speed control device and a hand brake to stop rotation when switched off. The electric motor is of 0.25 HP capacity coupled to a geared assembly. Suitable for operation on 230 Volts, 50 Hz, AC single phase.

Recommended Accessories & Consumables

The following accessories and consumables are not part of the standard supply and are mandatory for the testing work

Bitumen Testing Equipments

#Marshal compactor _ Automatic #Automatic marshal compactor #AUTOMATIC MARSHAL COMPACTOR #Automatic Marshal Compactor #Benkelman Beam Apparatus #Bitumen Extractor Electrically Operated #Bitumen Extractor Hand Operated #Bitumen Penetrometer #Camber Board #Centrifuge Extractor #Cleaveland Flash & Fire Point Apparatus #Conradson Carbon Residue Apparatus #Core Drilling Machine #Dean & Stark Apparatus #Distillation for Cut Back Bitumen #Distillation for Road Tar #Ductility Testing Machine #Ductility Testing Machine-Refrigerated #Elastic Recovery Mould #Float Test Apparatus #Hardness Tester For Mastic Asphalt #Kinematic Viscosity Bath #Loss on Heating Test #Low Temperature Water Bath #Marshall Stability Test Apparatus #Marshall Stability Test Apparatus Digital #Pensky Marten Flash Point Apparatus #Petroleum Distillation Apparatus #Planetary Mixer #Ring And Ball Apparatus #Softening Point Apparatus #Specific Gravity Bottle #Standard Penetrometer With Automatic Timer #Straight Edge #Tar Viscometer #Thin Film Oven #U-Tube viscometer #Vacuum Pump

Introduction

The Centrifuge Extractors are used for determination of bitumen percentage in hot mixed paving mixtures and pavement samples. The mix is added with a solvent and dissolved bitumen is removed by centrifugal action. The Extractors are available in two versions, Hand operated and motorised electrically driven.

General Description & Specification

Hand driven

The Centrifuge Extractor comprises of a precision machine rotor bowl and bowl cover housed in a cylindrical aluminum box. A knurled nut is provided to press filter paper disc between the rotor bowl and cover plate and the complete bowl assembly is removable for determination of weight of sample. The bowl assembly is mounted on a vertical shaft, which comes out from a casted housing. The shaft attached to the bowl is rotated manually by a handle. The gears operate in a casted housing in oil bath with splash lubrication. A drain is provided to collect dissolved bitumen coming out from the rotating bowl. The range of speed is 2400 – 3600 RPM. The bowl capacity is 1.5 Liter

Motorised electrically driven

The motorised version is provided with a variable speed control device and a hand brake to stop rotation when switched off. The electric motor is of 0.25 HP capacity coupled to a geared assembly. Suitable for operation on 230 Volts, 50 Hz, AC single phase.

Recommended Accessories & Consumables

The following accessories and consumables are not part of the standard supply and are mandatory for the testing work

Bitumen Testing Equipments

#Marshal compactor _ Automatic #Automatic marshal compactor #AUTOMATIC MARSHAL COMPACTOR #Automatic Marshal Compactor #Benkelman Beam Apparatus #Bitumen Extractor Electrically Operated #Bitumen Extractor Hand Operated #Bitumen Penetrometer #Camber Board #Centrifuge Extractor #Cleaveland Flash & Fire Point Apparatus #Conradson Carbon Residue Apparatus #Core Drilling Machine #Dean & Stark Apparatus #Distillation for Cut Back Bitumen #Distillation for Road Tar #Ductility Testing Machine #Ductility Testing Machine-Refrigerated #Elastic Recovery Mould #Float Test Apparatus #Hardness Tester For Mastic Asphalt #Kinematic Viscosity Bath #Loss on Heating Test #Low Temperature Water Bath #Marshall Stability Test Apparatus #Marshall Stability Test Apparatus Digital #Pensky Marten Flash Point Apparatus #Petroleum Distillation Apparatus #Planetary Mixer #Ring And Ball Apparatus #Softening Point Apparatus #Specific Gravity Bottle #Standard Penetrometer With Automatic Timer #Straight Edge #Tar Viscometer #Thin Film Oven #U-Tube viscometer #Vacuum Pump