AC/DC Clamp Meter 375 True RMS

0.00৳ 

Fluke 375 True RMS AC/DC Clamp Meter
  • Brand: Fluke
  • Branch: Industrial Grade
  • Category: Clamp Meters
  • Sub Category: General Purpose
  • Be prepared for all the accurate result all the time.

Fluke 375 True RMS AC/DC Clamp Meter comes with the Three-year warranty. The most important things about the Fluke 375 clamp meter, that always provide an accurate result at any environment.

With True RMS AC voltage and current measurements, the Fluke 375 Clamp Meter will scan up to 600 V and 600 A in each AC and DC modes, and is capable of frequency activity up to five hundred cycles per second.

In addition, the 375 is compatible with the new iFlex versatile current probe (sold separately), that expands the activity vary to 2500 A AC.

Features and benefits:

  • iFlex flexible current probe expands the measurement range to 2500 A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.
  • CAT IV 600 V, CAT III 1000 V
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Three-year warranty
  • True RMS AC voltage and current for accurate measurements on non-linear signals
  • 500 mV DC measurement range to interface with other accessories
  • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Soft carrying case

Specifications: Fluke 375 True RMS AC/DC Clamp Meter

Electrical Specifications
AC Current via Jaw
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only)
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 374 and 375 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
376 0.1 A (≤ 999.9 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A (375 and 376 only)
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
Measurement uncertainty assumes centralized primary conductor at the optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1% ± 5 digits
mV dc
Range 375 and 376 500.0 mV
Resolution 0.1 mV
Accuracy 1% ± 5 digits
Frequency via Jaw
Range 375 and 376 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 375 and 376 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A
Resistance
Range 374
375 and 376
6000 Ω
60 kΩ
Resolution 374 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
375 and 376 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy 1% ± 5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ± 4 digits
Mechanical Specifications
Size (L x W x H) 246 mm x 83 m x 43 mm
Weight 388 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature 10°C – +50°C
Storage Temp -40°C – +60°C
Operating Humidity Non condensing (< 10 –°C)
≤ 90% RH (at 10°C – 30°C)
≤ 75% RH (at 30°C – 40°C)
≤ 45% RH (at 40°C – 50°C)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMC EN 61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each
degree C above 28°C or below 18°C
Safety Specifications
Safety Compliance CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01):2004
EN/IEC 61010-1:2001 to
1000V Measurement Category (CAT) III
600V Measurement Category (CAT) IV
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
Agency Approvals
Batteries 2 AA, NEDA 15A, IEC LR6

Includes:

Models: Fluke 375 True RMS AC/DC Clamp Meter Includes:

  • Coated instruction card
  • Safety information sheet
  • Soft carrying case
  • TL75 test leads
  • Two AA Alkaline batteries

Others related Meter

  • Fluke 368 FC Leakage Current Clamp Meter
  • Fluke 353 True RMS 2000 A Clamp Meter
  • Fluke 302 Plus Clamp Meter
  • Fluke 323 True RMS Clamp Meter
  • Fluke 325 True RMS Clamp Meter
  • Fluke 365 Detachable Jaw True RMS AC/DC…
  • Fluke 355 True RMS 2000 A Clamp Meter
  • Fluke 773 Milliamp Process Clamp Meter
  • Fluke 375 True RMS AC/DC Clamp Meter
  • Fluke 772 Milliamp Clamp Meter
  • Fluke a3001 FC Wireless iFlex® AC Curren…
  • Fluke 381 Remote Display True RMS AC/DC…
  • Fluke 373 True-RMS AC Clamp Meter
  • Fluke 376 True RMS AC/DC Clamp Meter
  • Fluke 303 Clamp Meter
  • Fluke 305 Clamp Meter
  • Fluke 317 Clamp Meter
  • Fluke 319 Clamp Meter
  • Fluke 902 FC True-RMS HVAC Clamp Meter

OTHERS Social LINKS

 

Fluke 375 True RMS AC/DC Clamp Meter
  • Brand: Fluke
  • Branch: Industrial Grade
  • Category: Clamp Meters
  • Sub Category: General Purpose
  • Be prepared for all the accurate result all the time.

Fluke 375 True RMS AC/DC Clamp Meter comes with the Three-year warranty. The most important things about the Fluke 375 clamp meter, that always provide an accurate result at any environment.

With True RMS AC voltage and current measurements, the Fluke 375 Clamp Meter will scan up to 600 V and 600 A in each AC and DC modes, and is capable of frequency activity up to five hundred cycles per second.

In addition, the 375 is compatible with the new iFlex versatile current probe (sold separately), that expands the activity vary to 2500 A AC.

Features and benefits:

  • iFlex flexible current probe expands the measurement range to 2500 A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.
  • CAT IV 600 V, CAT III 1000 V
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Three-year warranty
  • True RMS AC voltage and current for accurate measurements on non-linear signals
  • 500 mV DC measurement range to interface with other accessories
  • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Soft carrying case

Specifications: Fluke 375 True RMS AC/DC Clamp Meter

Electrical Specifications
AC Current via Jaw
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only)
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 374 and 375 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
376 0.1 A (≤ 999.9 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A (375 and 376 only)
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
Measurement uncertainty assumes centralized primary conductor at the optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1% ± 5 digits
mV dc
Range 375 and 376 500.0 mV
Resolution 0.1 mV
Accuracy 1% ± 5 digits
Frequency via Jaw
Range 375 and 376 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 375 and 376 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A
Resistance
Range 374
375 and 376
6000 Ω
60 kΩ
Resolution 374 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
375 and 376 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy 1% ± 5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ± 4 digits
Mechanical Specifications
Size (L x W x H) 246 mm x 83 m x 43 mm
Weight 388 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature 10°C – +50°C
Storage Temp -40°C – +60°C
Operating Humidity Non condensing (< 10 –°C)
≤ 90% RH (at 10°C – 30°C)
≤ 75% RH (at 30°C – 40°C)
≤ 45% RH (at 40°C – 50°C)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMC EN 61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each
degree C above 28°C or below 18°C
Safety Specifications
Safety Compliance CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01):2004
EN/IEC 61010-1:2001 to
1000V Measurement Category (CAT) III
600V Measurement Category (CAT) IV
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
Agency Approvals
Batteries 2 AA, NEDA 15A, IEC LR6

Includes:

Models: Fluke 375 True RMS AC/DC Clamp Meter Includes:

  • Coated instruction card
  • Safety information sheet
  • Soft carrying case
  • TL75 test leads
  • Two AA Alkaline batteries

Others related Meter

  • Fluke 368 FC Leakage Current Clamp Meter
  • Fluke 353 True RMS 2000 A Clamp Meter
  • Fluke 302 Plus Clamp Meter
  • Fluke 323 True RMS Clamp Meter
  • Fluke 325 True RMS Clamp Meter
  • Fluke 365 Detachable Jaw True RMS AC/DC...
  • Fluke 355 True RMS 2000 A Clamp Meter
  • Fluke 773 Milliamp Process Clamp Meter
  • Fluke 375 True RMS AC/DC Clamp Meter
  • Fluke 772 Milliamp Clamp Meter
  • Fluke a3001 FC Wireless iFlex® AC Curren...
  • Fluke 381 Remote Display True RMS AC/DC...
  • Fluke 373 True-RMS AC Clamp Meter
  • Fluke 376 True RMS AC/DC Clamp Meter
  • Fluke 303 Clamp Meter
  • Fluke 305 Clamp Meter
  • Fluke 317 Clamp Meter
  • Fluke 319 Clamp Meter
  • Fluke 902 FC True-RMS HVAC Clamp Meter

OTHERS Social LINKS

 

Reviews

There are no reviews yet.

Be the first to review “AC/DC Clamp Meter 375 True RMS”

Your email address will not be published. Required fields are marked *