Technical Data
| Item | UPS 650VA-2000VA |
| Input/ Output wiring | L+N+PE |
| Input Voltage | UPS650/UPS1200/UPS1500/UPS2000/ 140~280Vac |
| Input Frequency | 50/60±10%Hz |
| Output Voltage | 220/230 ±10% Vac (Battery mode) |
| Output Frequency | Synchronizing with input AC while it is normal, and 50/60±0.5%Hz on battery mode |
| Transfer Time | Typical 6ms, including detection time and switching time (Synchronous switch-over) |
| Waveform | Square wave / Pure sine wave (Option-2) |
| Battery Voltage | UPS 650 VA12Vdc |
| UPS1200: 24Vdc | |
| UPS1500/UPS2000: 24/48Vdc | |
| Max. Charging Current | UPS 650/1200VA/1500VA/ 2000 VA : 1A (Short backup) |
| UPS 650/1200VA/1500VA/ 2000 VA : 6-8A (Long backup) | |
| Display | LED indicators show status of AC input, inverter, low battery and overload |
| RS 232 (USB, SNMP adaptor are optional) |
HIGH RELIABILITY
- Advanced digital control technology
- Comprehensive equipment protection function
- Flexible and practical cold start function
EXCELLENT PERFORMANCE
- Stable operation without noise
- Green idea environment design
- Wide voltage range for intellectual regulation (Smart AVR)
EASY FOR USE
- Small size, easy operation
- Intelligent and use-friendly power management (optional)
Technical Data
| Item | UPS 650VA-2000VA |
| Input/ Output wiring | L+N+PE |
| Input Voltage | UPS650/UPS1200/UPS1500/UPS2000/ 140~280Vac |
| Input Frequency | 50/60±10%Hz |
| Output Voltage | 220/230 ±10% Vac (Battery mode) |
| Output Frequency | Synchronizing with input AC while it is normal, and 50/60±0.5%Hz on battery mode |
| Transfer Time | Typical 6ms, including detection time and switching time (Synchronous switch-over) |
| Waveform | Square wave / Pure sine wave (Option-2) |
| Battery Voltage | UPS 650 VA12Vdc |
| UPS1200: 24Vdc | |
| UPS1500/UPS2000: 24/48Vdc | |
| Max. Charging Current | UPS 650/1200VA/1500VA/ 2000 VA : 1A (Short backup) |
| UPS 650/1200VA/1500VA/ 2000 VA : 6-8A (Long backup) | |
| Display | LED indicators show status of AC input, inverter, low battery and overload |
| RS 232 (USB, SNMP adaptor are optional) |