Heavy Duty Waterproof pH Meter

0.00৳ 

Features:

  • User-selectable calibration time out
  • Automatic calibration
  • Automatic Temperature Compensation
  • Tutorial messages on LCD
  • BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings
  • Battery % displayed on startup.

The HI 9124 is a waterproof pH meter. A large dual-level LCD displays both the pH and temperature along with an operational guide. Graphic symbols are displayed to help the users during the calibration process.

The pH calibration procedure is automatic with five memorized pH buffer values
and buffer recognition to simplify the calibration process.

This meter utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for accurate, consistent results.

Specifications:

Range
 
pH
-2.00 to 16.00 pH
Temperature
20.0 to 120.0°C / -4.0°F to 248.0°F
Resolution
 
pH
0.01 pH
Temperature
0.1°C / 0.1°F
Accuracy @ 20°C
 
pH
±0.01 pH
Temperature
±0.4°C / ±0.8°F (excluding probe error)
pH Calibration
automatic 1 or 2 point with 5 memorized buffer values (4.01, 6.86, 7.01, 9.18, 10.01)
Offset Calibration
±1 pH
Slope Calibration
From 80 to 108%
Temperature Compensation
automatic or manual, -20 to 120°C (-4 to 248°F)
pH Electrode
HI 1230B, double junction, gel filled, BNC connector and 1 m (3.3) cable (included)
Temperature Probe
HI 7662 with 1 m (3.3) cable (included)
Input Impedance
1012 Ohm
Battery Type / Life
1.5V AAA (3) / approximately 200 hours of continuous use. Auto-off after 20 minutes of non-use (can be disabled)
Environment
0 to 50°C (32 to 122°F); RH max 100%
Dimensions
185 x 72 x 36 mm (7.3 x 2.8 x 1.4)
Weight
300 g (10.6 oz.)

Features:

  • User-selectable calibration time out
  • Automatic calibration
  • Automatic Temperature Compensation
  • Tutorial messages on LCD
  • BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings
  • Battery % displayed on startup.

The HI 9124 is a waterproof pH meter. A large dual-level LCD displays both the pH and temperature along with an operational guide. Graphic symbols are displayed to help the users during the calibration process.

The pH calibration procedure is automatic with five memorized pH buffer values
and buffer recognition to simplify the calibration process.

This meter utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for accurate, consistent results.

Specifications:

Range
 
pH
-2.00 to 16.00 pH
Temperature
20.0 to 120.0°C / -4.0°F to 248.0°F
Resolution
 
pH
0.01 pH
Temperature
0.1°C / 0.1°F
Accuracy @ 20°C
 
pH
±0.01 pH
Temperature
±0.4°C / ±0.8°F (excluding probe error)
pH Calibration
automatic 1 or 2 point with 5 memorized buffer values (4.01, 6.86, 7.01, 9.18, 10.01)
Offset Calibration
±1 pH
Slope Calibration
From 80 to 108%
Temperature Compensation
automatic or manual, -20 to 120°C (-4 to 248°F)
pH Electrode
HI 1230B, double junction, gel filled, BNC connector and 1 m (3.3) cable (included)
Temperature Probe
HI 7662 with 1 m (3.3) cable (included)
Input Impedance
1012 Ohm
Battery Type / Life
1.5V AAA (3) / approximately 200 hours of continuous use. Auto-off after 20 minutes of non-use (can be disabled)
Environment
0 to 50°C (32 to 122°F); RH max 100%
Dimensions
185 x 72 x 36 mm (7.3 x 2.8 x 1.4)
Weight
300 g (10.6 oz.)