COD Test Tube Digestion Reactor

0.00৳ 

Features:

  • Low temperature alert appears when the block is warming up. It alerts the user that the temperature is below the set value.
  • High temperature alert appears when the block is warming up. It alerts the user that the temperature is above the set value.
  • Countdown timer shows time remaining until the heating element shuts off.

The HI 839800 COD reactor is constructed of durable materials.  The aluminum block incorporates a 25-vial capacity and a well for a reference temperature probe.

The HI 839800 COD reactor is an easy-to-use test tube heater.  Its well-marked user interface provides intuitive operation.  The reactor is equipped with two predefined temperature settings:  150°C and 105°C.  COD and total phosphorus digestions are conducted at 150°C, and total nitrogen digestions are at 105°C.

In addition, the HI 839800 has 3 LED’s for visual indication.  A green LED indicates power, a blinking red LED warns the user of a hot heater block (above 50°C), and a yellow LED indicates heating.

A three-hour countdown timer is also incorporated to control timed digestions.  When the countdown timer expires, a beep will sound and the heating element will turn off.

The reactor contains a thermal fuse that prevents overheating by turning off the heating element.

Block temperature is continuously displayed on the LCD even when there is no active temperature program running.

Please Note:  An optional labortory bench safety shield, HI 740217, is highly recommended for use with the reactor to provide added safety in the event of overheating.
Specifications:

Temperature of Reaction 105°C or 150°C (221°F or 302°F)
Temperature Stability ±0.5°C (±0.9°F)
Temperature Range -10°C to 160°C (14°F to 320°F)
Accuracy ±2°C (±3.6°F)
Capacity 25 vials (dia 16 x 100 mm), one receptacle for a stainless steel reference thermometer
Warm-up Time 10-15 minutes, depending on selected temperature
Operating Mode timed (0 to 180 minutes) or infinity mode
Block aluminum
Environment 5 to 50°C (41 to 122°F)
Power Supply
(fuse protected)
HI 839800-01: 115 VAC; 60 Hz; 250 W
HI 839800-02: 230 VAC; 50 Hz; 250 W
Dimensions 190 x 300 x 95 mm (7.5 x 11.8 x 3.7″)
Weight approximately 4.8 kg (10.6 lb.)

Features:

  • Low temperature alert appears when the block is warming up. It alerts the user that the temperature is below the set value.
  • High temperature alert appears when the block is warming up. It alerts the user that the temperature is above the set value.
  • Countdown timer shows time remaining until the heating element shuts off.

The HI 839800 COD reactor is constructed of durable materials.  The aluminum block incorporates a 25-vial capacity and a well for a reference temperature probe.

The HI 839800 COD reactor is an easy-to-use test tube heater.  Its well-marked user interface provides intuitive operation.  The reactor is equipped with two predefined temperature settings:  150°C and 105°C.  COD and total phosphorus digestions are conducted at 150°C, and total nitrogen digestions are at 105°C.

In addition, the HI 839800 has 3 LED's for visual indication.  A green LED indicates power, a blinking red LED warns the user of a hot heater block (above 50°C), and a yellow LED indicates heating.

A three-hour countdown timer is also incorporated to control timed digestions.  When the countdown timer expires, a beep will sound and the heating element will turn off.

The reactor contains a thermal fuse that prevents overheating by turning off the heating element.

Block temperature is continuously displayed on the LCD even when there is no active temperature program running.

Please Note:  An optional labortory bench safety shield, HI 740217, is highly recommended for use with the reactor to provide added safety in the event of overheating.
Specifications:

Temperature of Reaction 105°C or 150°C (221°F or 302°F)
Temperature Stability ±0.5°C (±0.9°F)
Temperature Range -10°C to 160°C (14°F to 320°F)
Accuracy ±2°C (±3.6°F)
Capacity 25 vials (dia 16 x 100 mm), one receptacle for a stainless steel reference thermometer
Warm-up Time 10-15 minutes, depending on selected temperature
Operating Mode timed (0 to 180 minutes) or infinity mode
Block aluminum
Environment 5 to 50°C (41 to 122°F)
Power Supply
(fuse protected)
HI 839800-01: 115 VAC; 60 Hz; 250 W
HI 839800-02: 230 VAC; 50 Hz; 250 W
Dimensions 190 x 300 x 95 mm (7.5 x 11.8 x 3.7")
Weight approximately 4.8 kg (10.6 lb.)

Reviews

There are no reviews yet.

Be the first to review “COD Test Tube Digestion Reactor”

Your email address will not be published. Required fields are marked *